ChemicalBook >>Hexamethylphosphorous triamide>>Tris(dimethylamino)phosphine(1608-26-0)

Tris(dimethylamino)phosphine(1608-26-0)

Tris(dimethylamino)phosphine(1608-26-0)
Product IdentificationBack to Contents
【Product Name】

Tris(dimethylamino)phosphine
【Synonyms】

Hexamethylphosphorous triamide
Hexamethyltriamidophosphite
Hexamethyltriaminophosphine
HMPT
Tris(dimethylamino)phosphine
Trisdimethylaminophosphorus
【CAS】

1608-26-0
【Formula】

C6H18N3P
【Molecular Weight】

163.19999999999999
【EINECS】

216-534-4
【RTECS】

TH3390000
【RTECS Class】

Mutagen
【Beilstein/Gmelin】

906778
【Beilstein Reference】

4-04-00-00274
【EC Class】

flammable
Physical and Chemical PropertiesBack to Contents
【Appearance】

Colorless liquid.
【Solubility in water】

Very soluble
【Melting Point】

-44
【Boiling Point】

150
【Vapor Pressure】

3 (20 C)
【Density】

0.8962 g/cm3
【pKa/pKb】

2.94 (pKb)
【Heat Of Vaporization】

61.10 kJ/mol
【Refractive Index】

1.4599
First Aid MeasuresBack to Contents
【Ingestion】

Do NOT induce vomiting. If victim is conscious and alert, give 2-4 cupfuls of milk or water. Never give anything by mouth to an unconscious person. Get medical aid immediately.
【Inhalation】

Get medical aid immediately. Remove from exposure to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.
【Skin】

Get medical aid. Immediately flush skin with plenty of soap and water for at least 15 minutes while removing contaminated clothing and shoes.
【Eyes】

Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid immediately.
Handling and StorageBack to Contents
【Storage】

Keep away from heat, sparks, and flame. Keep container closed when not in use. Flammables-area. Storage under a nitrogen blanket has been recommended.
【Handling】

Wash thoroughly after handling. Use only in a well ventilated area. Avoid contact with eyes, skin, and clothing. Empty containers retain product residue, (liquid and/or vapor), and can be dangerous. Avoid contact with heat, sparks and flame. Avoid ingestion and inhalation. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose empty containers to heat, sparks or open flames.
Hazards IdentificationBack to Contents
【Ingestion】

May cause irritation of the digestive tract.
【Inhalation】

Vapor or mist is irritating to the mucous membranes and upper respiratory tract.
【Skin】

Causes skin irritation.
【Eyes】

Vapors cause eye irritation.
【Hazards】

Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers.
【EC Risk Phrase】

R 10 36/37/38
【EC Safety Phrase】

S 23 26 36
【UN (DOT)】

1993
Exposure Controls/Personal ProtectionBack to Contents
【Personal Protection】

Eyes: Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166. Skin: Wear appropriate protective gloves to prevent skin exposure. Clothing: Wear appropriate protective clothing to prevent skin exposure.
【Respirators】

Follow the OSHA respirator regulations found in 29CFR 1910.134 or European Standard EN 149. Always use a NIOSH or European Standard EN 149 approved respirator when necessary.
Fire Fighting MeasuresBack to Contents
【Flash Point】

43
【Fire Fighting】

Wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. During a fire, irritating and highly toxic gases may be generated by thermal decomposition or combustion. Extinguishing media: Use water spray to cool fire-exposed containers. Use dry chemical, carbon dioxide, or alcohol-resistant foam.
【Fire Potential】

HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
Accidental Release MeasuresBack to Contents
【Small spills/leaks】

Absorb spill with inert material, (e.g., dry sand or earth), then place into a chemical waste container. Wash area with soap and water. Clean up spills immediately, using the appropriate protective equipment. Remove all sources of ignition. Use a spark-proof tool. Provide ventilation.
Stability and ReactivityBack to Contents
【Disposal Code】

25
【Stability】

Stable under normal temperatures and pressures.
【Incompatibilities】

Strong oxidizing agents.
【Decomposition】

Nitrogen oxides, phosphine, carbon monoxide, oxides of phosphorus, irritating and toxic fumes and gases, carbon dioxide.
【Combustion Products】

Fire may produce irritating, corrosive and/or toxic gases.
Transport InformationBack to Contents
【UN Number】

1993
【Hazard Class】

3
【Packing Group】

I; II; III
【HS Code】

2929 90 00
Company Name: Shaanxi Rock New Materials Co., Ltd.
Tel: 917-917-8888777 18691746767
Fax:
WebSite: www.bjrock.com/
Company Name: Xinxiang Runyu Material Co., Ltd.
Tel: 166-166-37336996 15690792173
Fax: 0373-7759608
WebSite: http://www.runvmat.com/
Company Name: Creasyn Finechem(Tianjin) Co., Ltd.
Tel: 022-022-83946278 13820372920
Fax: 022-83945176
WebSite: www.creasyn.com/
Company Name: J & K SCIENTIFIC LTD.
Tel: 010-82848833 400-666-7788
Fax: 86-10-82849933
WebSite: http://www.jkchemical.com
Company Name: Meryer (Shanghai) Chemical Technology Co., Ltd.
Tel: 4006608290; 18621169109
Fax: 86-21-61259102
WebSite: https://www.meryer.com/cn/index/
Company Name: Beijing Donghualituo Techonlogy Development Co.,Ltd.
Tel: 010-88425576
Fax: (+86)-10-88425546
WebSite: www.dhltchem.com
Company Name: Alfa Aesar
Tel: 400-6106006
Fax: 021-67582001/03/05
WebSite: http://chemicals.thermofisher.cn
Company Name: TCI (Shanghai) Development Co., Ltd.
Tel: 021-67121386
Fax: 021-67121385
WebSite: https://www.tcichemicals.com/CN/zh/