| Identification | Back Directory | [Name]
1,2,3,7,8-PENTACHLORODIBENZO-P-DIOXIN | [CAS]
40321-76-4 | [Synonyms]
1,2,3,7,8-PCDD 1,2,3,7,8-PNCDD 1,2,3,7,8-PECDD 1,2,3,7,8-Pentachlorooxanthrene 1,2,3,7,8-PENTACHLORODIBENZODIOXIN 1,2,3,7,8-pentachloro-dibenzo-p-dioxi Pentachlorobenzo-p-dioxin, 1,2,3,7,8- 2,3,4,7,8-Pentachlorodibenzo[1,4]dioxin 1,2,3,7,8-PENTACHLORODIBENZO-PARA-DIOXIN Dibenzo-p-dioxin, 1,2,3,7,8-pentachloro- 1,2,3,7,8-Pentachlorodibenzo[b,e][1,4]dioxin Dibenzo[b,e][1,4]dioxin, 1,2,3,7,8-pentachloro- | [Molecular Formula]
C12H3Cl5O2 | [MDL Number]
MFCD01310419 | [MOL File]
40321-76-4.mol | [Molecular Weight]
356.42 |
| Hazard Information | Back Directory | [Uses]
A toxic polychlorinated dibenzo-p-dioxin detected in domestic meat and poultry. | [Definition]
ChEBI: 1,2,3,7,8-Pentachlorodibenzodioxin is a polychlorinated dibenzodioxine. | [Safety Profile]
Poison by ingestion. Questionable carcinogen. When heated to decomposition it emits toxic fumes of Clí. | [References]
[1] KARIN I. VAN EDE. Differential relative effect potencies of some dioxin-like compounds in human peripheral blood lymphocytes and murine splenic cells[J]. Toxicology letters, 2014, 226 1: Pages 43-52. DOI: 10.1016/j.toxlet.2014.01.026 [2] RAIMO POHJANVIRTA Jouko T Mikko Unkila. Comparative Acute Lethality of 2,3,7,8-Tetrachlorodibenzo-p-dioxin (TCDD), 1,2,3,7,8-Pentachlorodibenzo-p-dioxin and 1,2,3,4,7,8-Hexachlorodibenzo-p-dioxin in the Most TCDD-Susceptible and the Most TCDD-Resistant Rat Strain[J]. Basic & Clinical Pharmacology & Toxicology, 1993, 73 1: 52-56. DOI: 10.1111/j.1600-0773.1993.tb01958.x [3] TIMOTHY ZACHAREWSKI. Comparative analysis of polychlorinated dibenzo-p-dioxin and dibenzofuran congeners in Great Lakes fish extracts by gas chromatography-mass spectrometry and in vitro enzyme induction activities[J]. 环境科学与技术, 1989, 23 6: 730-735. DOI: 10.1021/es00064a012 [4] M. PAJUREK S. M M Warenik Bany. Feed as a source of dioxins and PCBs[J]. Chemosphere, 2022, 308: Article 136243. DOI: 10.1016/j.chemosphere.2022.136243 [5] SUH-WOAN HU Chang C C Guo Ping ChangChien. PCDD/Fs levels in indoor environments and blood of workers of three municipal waste incinerators in Taiwan[J]. Chemosphere, 2004, 55 4: Pages 611-620. DOI: 10.1016/j.chemosphere.2003.10.057 [6] TUNG SON VU . Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans in blood samples from historically herbicide-sprayed areas and rural and industrialized unsprayed areas in Vietnam[J]. Chemosphere, 2023, 326: Article 138331. DOI: 10.1016/j.chemosphere.2023.138331 |
|
| Company Name: |
AccuStandard Inc
|
| Tel: |
(800) 442-5290 |
| Website: |
www.accustandard.com |
|