Duolink In Situ Probemaker MINUS

Duolink In Situ Probemaker MINUS Struktur
CAS-Nr.
Englisch Name:
Duolink In Situ Probemaker MINUS
Synonyma:
Duolink? In Situ Probemaker MINUS
CBNumber:
CB02850542
Summenformel:
Molgewicht:
0
MOL-Datei:
Mol file

Duolink In Situ Probemaker MINUS Eigenschaften

storage temp. 
-20°C
Sicherheit
  • Risiko- und Sicherheitserklärung
  • Gefahreninformationscode (GHS)
Bildanzeige (GHS) GHS hazard pictogramsGHS hazard pictograms
Alarmwort Warnung
Gefahrenhinweise
Code Gefahrenhinweise Gefahrenklasse Abteilung Alarmwort Symbol P-Code
H317 Kann allergische Hautreaktionen verursachen. Sensibilisierung der Haut Kategorie 1A Warnung GHS hazard pictogramssrc="/GHS07.jpg" width="20" height="20" /> P261, P272, P280, P302+P352,P333+P313, P321, P363, P501
H411 Giftig für Wasserorganismen, mit langfristiger Wirkung. Langfristig (chronisch) gewässergefährdend Kategorie 2
Sicherheit
P261 Einatmen von Staub vermeiden.
P272 Kontaminierte Arbeitskleidung nicht außerhalb des Arbeitsplatzes tragen.
P273 Freisetzung in die Umwelt vermeiden.
P280 Schutzhandschuhe/Schutzkleidung/Augenschutz tragen.
P302+P352 BEI BERÜHRUNG MIT DER HAUT: Mit viel Wasser/... (Hersteller kann, falls zweckmäßig, ein Reinigungsmittel angeben oder, wenn Wasser eindeutig ungeeignet ist, ein alternatives Mittel empfehlen) waschen.
P333+P313 Bei Hautreizung oder -ausschlag: Ärztlichen Rat einholen/ärztliche Hilfe hinzuziehen.

Duolink In Situ Probemaker MINUS Chemische Eigenschaften,Einsatz,Produktion Methoden

Verwenden

To perform a complete Duolink? PLA in situ experiment you will need two primary antibodies (PLA, IHC, ICC or IF validated) that recognize two target epitopes. Other necessary reagents include a pair of PLA probes from different species (one PLUS and one MINUS), detection reagents, wash buffers, and mounting medium. Analysis is carried out using standard immunofluorescence assay equipment.HRP is also available for brightfield detection.

Specificity
Duolink? In Situ Probemaker extends your possibilities even further by allowing you to create your own PLA probes to meet specific assay requirements.
  • Study homodimers
  • Study protein-protein interactions with two primary antibodies derived from the same species
  • Study protein-protein interactions with primary antibodies from any species

Using Duolink? In Situ Probemaker PLUS and MINUS, you simply conjugate the PLUS and MINUS oligo arms directly to your antibodies in a quick and convenient procedure. As well as providing unique capabilities, this also means there is no longer any limitation as to which species your primary antibodies have to be derived from in order perform a Duolink? In Situ assay.

Application Note
The antibody to be conjugated must have a concentration of 1 mg/ml. Do not use volumes larger than 20 ml for conjugation. The antibody must be in an amine free buffer, ideally PBS. The buffer should be carrier free but may contain up to 0.1% BSA, 5% trehalose, and 0.02% sodium azide.
  • Study homodimers by using one monoclonal antibody split into two halves. Label one with the PLUS oligo and the other with the MINUS oligo.
  • Use antibodies from same species: study protein-protein interactions, protein modifications, or single proteins, using two primary antibodies derived from the same species. Label one of the antibodies with the PLUS oligo and the other with the MINUS oligo
  • Use antibodies from any species: study protein-protein interactions, protein modifications, or single proteins, using one or both primary antibodies derived from species other than mouse, rabbit or goat. Label one of your secondary antibodies with the PLUS oligo and the other with the MINUS oligo. Or, combine one labeled secondary antibody with a standard secondary Duolink? In Situ PLA probe.

Test your primary antibodies (IgG-class, mono- or polyclonal) in a standard immunofluorescence (IF), immunohistochemistry (IHC) or immunocytochemistry (ICC) assay to determine the optimal fixation, blocking, and titer conditions. Duolink? in situ reagents are suitable for use on fixed cells, cytospin cells, cells grown on slide, formalin-fixed, paraffin embedded (FFPE), or tissue (fresh or frozen). No minimum number of cells is required.

Let us do the work for you, learn more about our Custom Service Program to accelerate your Duolink? projects

View full Duolink? product list

Duolink In Situ Probemaker MINUS Upstream-Materialien And Downstream Produkte

Upstream-Materialien

Downstream Produkte


Duolink In Situ Probemaker MINUS Anbieter Lieferant Produzent Hersteller Vertrieb Händler.

Global( 2)Lieferanten
Firmenname Telefon E-Mail Land Produktkatalog Edge Rate
Sigma-Aldrich 021-61415566 800-8193336
orderCN@merckgroup.com China 51471 80

  • Duolink? In Situ Probemaker MINUS
Copyright 2019 © ChemicalBook. All rights reserved