ChemicalBook >>Carbon tetrafluoride>>Refrigerant R 14(75-73-0)

Refrigerant R 14(75-73-0)

Refrigerant R 14(75-73-0)
Product IdentificationBack to Contents
【Product Name】

Refrigerant R 14
【Synonyms】

Carbon tetrafluoride
Freon-14
Halon 14
Perfluoromethane
Tetrafluorocarbon
【CAS】

75-73-0
【Formula】

CF4
【Molecular Weight】

88
【EINECS】

200-896-5
【RTECS】

FG4920000
【RTECS Class】

Other
【Merck】

13,1827
【Beilstein/Gmelin】

1697288
【Beilstein Reference】

4-01-00-00026
Physical and Chemical PropertiesBack to Contents
【Appearance】

Colorless gas. Odorless.
【Solubility in water】

Insoluble
【Melting Point】

183.6
【Boiling Point】

-128.06
【Partition Coefficient】

1.18
【Heat Of Vaporization】

12.1 kJ/mol
【Usage】

Low temperature refrigerant, gaseous insulator.
【Vapor Density】

3.04
【Refractive Index】

1.113 (-53 C)
First Aid MeasuresBack to Contents
【Ingestion】

These substances may cause frostbite to the upper airway and gastrointestinal tract after ingestion. Administer oxygen and manage airway as clinically indicated. Emesis, activated charcoal, and gastric lavage are not recommended.
【Inhalation】

Move victim to fresh air. Apply artificial respiration if victim is not breathing. Administer oxygen if breathing is difficult.
【Skin】

Remove contaminated clothing and wash exposed area thoroughly with soap and water. A physician should examine the area if irritation or pain persists. If frostbite has occurred, refer to dermal treatment in the main body of this document for rewarming.
【Eyes】

If symptoms develop, immediately move individual away from exposure and into fresh air. Flush eyes gently with water for at least 15 minutes while holding eyelids apart; seek immediate medical attention.
Handling and StorageBack to Contents
【Storage】

Keep in a cool, dry, dark location in a tightly sealed container or cylinder. Keep away from incompatible materials, ignition sources and untrained individuals. Secure and label area. Protect containers/cylinders from physical damage.
【Handling】

All chemicals should be considered hazardous. Avoid direct physical contact. Use appropriate, approved safety equipment. Untrained individuals should not handle this chemical or its container. Handling should occur in a chemical fume hood.
Hazards IdentificationBack to Contents
【Inhalation】

Vapors may cause dizziness or asphyxiation without warning.
【Skin】

Dermal contact may result in defatting, irritation or contact dermatitis. Severe frostbite has been reported as an effect of freon exposure. Injection causes transient pain, erythema and edema.
【Eyes】

See Skin.
【Ingestion】

Nausea may develop. Ingestion of a small amount of trichlorofluoromethane resulted in necrosis and perforation of the stomach in one patient.
【Hazards】

Containers may explode when heated. Ruptured cylinders may rocket.
【EC Safety Phrase】

S 23 38
【UN (DOT)】

1982
Exposure Controls/Personal ProtectionBack to Contents
【Personal Protection】

Wear appropriate protective gloves, clothing and goggles.
【Respirators】

Wear positive pressure self-contained breathing apparatus (SCBA).
【Exposure Effects】

Headache, dizziness, and disorientation are common. Cerebral edema may be found on autopsy. Dichlorodifluoromethane was not teratogenic in rats and rabbits. <br>The reproductive effects of 1,1,1,2-tetrafluoroethane were studied in rats. No adverse effects on reproductive performance was noted or on the development, maturation or reproductive performance of up to two successive generations.
【Poison Class】

5
Fire Fighting MeasuresBack to Contents
【Autoignition】

>1100
【Fire Fighting】

Extinguish fire using agent suitable for type of surrounding fire. (Material itself does not burn or burns with difficulty.) Cool all affected containers with flooding quantities of water. Apply water from as far a distance as possible. Do not use water on material itself. Use water spray to knock-down vapors.
【Fire Potential】

May burn but does not ignite readily.
Accidental Release MeasuresBack to Contents
【Small spills/leaks】

Attempt to stop leak if without undue personnel hazard. Use water spray to knock-down vapors.
Stability and ReactivityBack to Contents
【Incompatibilities】

Incompatible with aluminum.
【Stability】

Thermally and chemically very inert.
【Decomposition】

When heated to decomposition it emits toxic fumes of hydrogen fluoride.
【Combustion Products】

Fire may produce irritating, corrosive and/or toxic gases.
Transport InformationBack to Contents
【UN Number】

1982
【Hazard Class】

2.2
Company Name: Guangzhou Yuejia Gas Co., Ltd
Tel: 400-6377517 19876107228
Fax:
WebSite: www.yigas.cn/
Company Name: Meryer (Shanghai) Chemical Technology Co., Ltd.
Tel: 4006608290; 18621169109
Fax: 86-21-61259102
WebSite: https://www.meryer.com/cn/index/
Company Name: Energy Chemical
Tel: 021-021-58432009 400-005-6266
Fax: 021-58436166
WebSite: http://www.energy-chemical.com
Company Name: Beijing Ouhe Technology Co., Ltd
Tel: 010-82967028 13552068683
Fax: +86-10-82967029
WebSite: http://www.ouhechem.com/
Company Name: JinYan Chemicals(ShangHai) Co.,Ltd.
Tel: 13817811078
Fax: 86-021-50426522,50426273
WebSite: www.jingyan-chemical.com
Company Name: Nanjing Vital Chemical Co., Ltd.
Tel: Please Send Email 18652950785
Fax: 025-87193546
WebSite: www.chemicalbook.com/ShowSupplierProductsList15337/0.htm
Company Name: Shanghai T&W Pharmaceutical Co., Ltd.
Tel: +86 21 61551611
Fax: +86 21 50676805
WebSite: www.trustwe.com
Company Name: Shanghai YuLue Chemical Co., Ltd.
Tel: 021-60345187 13671753212
Fax: 021-34702061
WebSite: https://www.chemicalbook.com/ShowSupplierProductsList16365/0.htm