ChemicalBook >>n-Butyl cyanoacetate>>Butyl cyanoacetate(5459-58-5)

Butyl cyanoacetate(5459-58-5)

Butyl cyanoacetate(5459-58-5)
Product IdentificationBack to Contents
【Product Name】

Butyl cyanoacetate
【Synonyms】

Acetic acid, cyano-, butyl ester
Butyl 2-cyanoacetate
n-Butyl a-cyanoacetate
【CAS】

5459-58-5
【Formula】

C7H11NO2
【Molecular Weight】

141.16
【EINECS】

226-730-1
【RTECS】

AG3692500
【RTECS Class】

Other
【Beilstein/Gmelin】

1761735
【Beilstein Reference】

4-02-00-01891
Physical and Chemical PropertiesBack to Contents
【Appearance】

Colorless liquid.
【Solubility in water】

Very soluble
【Melting Point】

-80
【Boiling Point】

230.7
【Density】

1.001 g/cm3 (20 C)
【pKa/pKb】

3.06 (pKa)
【Vapor Density】

4.8
【Refractive Index】

1.4241 (20 C)
First Aid MeasuresBack to Contents
【Ingestion】

Never give anything by mouth to an unconscious person. Get medical aid. Do NOT induce vomiting. If conscious and alert, rinse mouth and drink 2-4 cupfuls of milk or water.
【Inhalation】

Remove from exposure to fresh air immediately. If breathing is difficult, give oxygen. Get medical aid. DO NOT use mouth-to-mouth respiration. If breathing has ceased apply artificial respiration using oxygen and a suitable mechanical device such as a bag and a mask.
【Skin】

Get medical aid. Flush skin with plenty of soap and water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse.
【Eyes】

Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid.
Handling and StorageBack to Contents
【Storage】

Keep away from sources of ignition. Store in a tightly closed container. Store in a cool, dry, well-ventilated area away from incompatible substances.
【Handling】

Wash thoroughly after handling. Use only in a well ventilated area. Avoid breathing dust, vapor, mist, or gas. Avoid contact with eyes, skin, and clothing. Empty containers retain product residue, (liquid and/or vapor), and can be dangerous. Keep container tightly closed. Avoid contact with heat, sparks and flame. Avoid ingestion and inhalation. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose empty containers to heat, sparks or open flames.
Hazards IdentificationBack to Contents
【Inhalation】

May cause respiratory tract irritation. Aspiration may lead to pulmonary edema. May cause cardiac abnormalities. Inhalation at high concentrations may cause CNS depression and asphixiation.
【Skin】

May cause irritation and dermatitis. May cause cyanosis of the extremities.
【Eyes】

May cause eye irritation. May cause chemical conjunctivitis and corneal damage.
【Ingestion】

May cause gastrointestinal irritation with nausea, vomiting and diarrhea. May cause cardiac disturbances. Expected to be a low ingestion hazard. May cause central nervous system depression.
Exposure Controls/Personal ProtectionBack to Contents
【Personal Protection】

Eyes: Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166. Skin: Wear appropriate protective gloves to prevent skin exposure. Clothing: Wear appropriate protective clothing to prevent skin exposure.
【Respirators】

Follow the OSHA respirator regulations found in 29CFR 1910.134 or European Standard EN 149. Always use a NIOSH or European Standard EN 149 approved respirator when necessary.
【Exposure Effects】

Effects may be delayed.
Fire Fighting MeasuresBack to Contents
【Flash Point】

91
【Fire Fighting】

Wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. During a fire, irritating and highly toxic gases may be generated by thermal decomposition or combustion. Will burn if involved in a fire. Use water spray to keep fire-exposed containers cool. Combustible Liquid. Runoff from fire control or dilution water may cause pollution. Extinguishing media: Use water spray to cool fire-exposed containers. For small fires, use dry chemical, carbon dioxide, or water spray. For large fires, use dry chemical, carbon dioxide, alcohol-resistant foam, or water spray.
Accidental Release MeasuresBack to Contents
【Small spills/leaks】

Absorb spill with inert material, (e.g., dry sand or earth), then place into a chemical waste container. Avoid runoff into storm sewers and ditches which lead to waterways. Clean up spills immediately, using the appropriate protective equipment. Remove all sources of ignition. Use a spark-proof tool. Provide ventilation.
Stability and ReactivityBack to Contents
【Stability】

Stable at room temperature in closed containers under normal storage and handling conditions.
【Incompatibilities】

Strong bases, oxidizing agents.
【Decomposition】

Nitrogen oxides, carbon monoxide, irritating and toxic fumes and gases, carbon dioxide.
Company Name: China Synchem Technology Co.,Ltd.
Tel: +86-0552-4929304 +86-18055277008
Fax: +86-552-4928800
WebSite: http://www.cnsynchem.com
Company Name: Shandong Deju Renhe chemical raw materials Co., Ltd
Tel: 15253208962
Fax:
WebSite:
Company Name: J & K SCIENTIFIC LTD.
Tel: 010-82848833 400-666-7788
Fax: 86-10-82849933
WebSite: http://www.jkchemical.com
Company Name: Meryer (Shanghai) Chemical Technology Co., Ltd.
Tel: 4006608290; 18621169109
Fax: 86-21-61259102
WebSite: https://www.meryer.com/cn/index/
Company Name: TCI (Shanghai) Development Co., Ltd.
Tel: 021-67121386
Fax: 021-67121385
WebSite: https://www.tcichemicals.com/CN/zh/
Company Name: BeiJing Hwrk Chemicals Limted
Tel: 0757-86329057 18501085097
Fax: 010-89508210
WebSite: www.hwrkchemical.com
Company Name: Energy Chemical
Tel: 021-021-58432009 400-005-6266
Fax: 021-58436166
WebSite: http://www.energy-chemical.com
Company Name: Jia Xing Isenchem Co.,Ltd
Tel: 0573-85285100 18627885956
Fax: 0573-85285100
WebSite: https://www.chemicalbook.com/ShowSupplierProductsList14265/0.htm