ChemicalBook >>2-Methoxypropene>>2-Methoxy-1-propene(116-11-0)

2-Methoxy-1-propene(116-11-0)

2-Methoxy-1-propene(116-11-0)
Product IdentificationBack to Contents
【Product Name】

2-Methoxy-1-propene
【Synonyms】

2-Methoxyprop-1-ene
2-Methoxypropene
Isopropenyl methyl ether
Methyl 1-methylvinyl ether
Methyl isopropenyl ether
【CAS】

116-11-0
【Formula】

C4H8O
【Molecular Weight】

72.099999999999994
【EINECS】

204-125-3
【RTECS】

UD0800000
【RTECS Class】

Other
【Beilstein/Gmelin】

1734635
【Beilstein Reference】

4-01-00-02075
Physical and Chemical PropertiesBack to Contents
【Appearance】

Clear, colorless liquid.
【Solubility in water】

Soluble
【Boiling Point】

34
【Density】

0.77 g/cm3 (20 C)
【Usage】

Major uses include laboratory reagent (hydroxyl-protecting), chemical intermediate for 2-methoxyallyl bromide (an alkylating agent).
【Vapor Density】

2.49
【Refractive Index】

1.3881 (20 C)
First Aid MeasuresBack to Contents
【Ingestion】

Do NOT induce vomiting. If victim is conscious and alert, give 2-4 cupfuls of milk or water. Never give anything by mouth to an unconscious person. Get medical aid.
【Inhalation】

Remove from exposure to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical aid.
【Skin】

Get medical aid. Flush skin with plenty of soap and water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse.
【Eyes】

Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid.
Handling and StorageBack to Contents
【Storage】

Keep away from heat, sparks, and flame. Keep away from sources of ignition. Store in a tightly closed container. Store in a cool, dry, well-ventilated area away from incompatible substances. Flammables-area. Refrigerator (approx 4 C). Store protected from light.
【Handling】

Wash thoroughly after handling. Remove contaminated clothing and wash before reuse. Use only in a well ventilated area. Ground and bond containers when transferring material. Avoid contact with eyes, skin, and clothing. Empty containers retain product residue, (liquid and/or vapor), and can be dangerous. Keep container tightly closed. Avoid contact with heat, sparks and flame. Avoid ingestion and inhalation. Store protected from light. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose empty containers to heat, sparks or open flames.
Hazards IdentificationBack to Contents
【Inhalation】

May cause respiratory tract irritation. Vapors may cause dizziness or suffocation.
【Skin】

May cause skin irritation.
【Eyes】

May cause eye irritation.
【Ingestion】

May cause irritation of the digestive tract. May be harmful if swallowed.
【Hazards】

Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers.
【EC Risk Phrase】

R 12 22
【EC Safety Phrase】

S 9 16 29 33
【UN (DOT)】

1993
Exposure Controls/Personal ProtectionBack to Contents
【Personal Protection】

Eyes: Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166. Skin: Wear appropriate protective gloves to prevent skin exposure. Clothing: Wear appropriate protective clothing to prevent skin exposure.
【Respirators】

A respiratory protection program that meets OSHA's 29 CFR 1910.134 and ANSI Z88.2 requirements or European Standard EN 149 must be followed whenever workplace conditions warrant a respirator's use.
【Exposure Effects】

Effects may be delayed.
【Poison Class】

4
Fire Fighting MeasuresBack to Contents
【Flash Point】

-29
【Autoignition】

190
【Fire Fighting】

Wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. During a fire, irritating and highly toxic gases may be generated by thermal decomposition or combustion. Extremely flammable. Material will readily ignite at room temperature. Use water spray to keep fire-exposed containers cool. Water may be ineffective. Material is lighter than water and a fire may be spread by the use of water. Containers may explode in the heat of a fire. Will be easily ignited by heat, sparks or flame. Extinguishing media: For small fires, use dry chemical, carbon dioxide, water spray or alcohol-resistant foam. For large fires, use water spray, fog, or alcohol-resistant foam. Use water spray to cool fire-exposed containers.
【Fire Potential】

HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
Accidental Release MeasuresBack to Contents
【Small spills/leaks】

Absorb spill with inert material, (e.g., dry sand or earth), then place into a chemical waste container. Avoid runoff into storm sewers and ditches which lead to waterways. Clean up spills immediately, using the appropriate protective equipment. Remove all sources of ignition. Use a spark-proof tool. Provide ventilation. A vapor suppressing foam may be used to reduce vapors.
Stability and ReactivityBack to Contents
【Incompatibilities】

Oxidizing agents, strong acids.
【Stability】

Stable under normal temperatures and pressures.
【Decomposition】

Carbon monoxide, irritating and toxic fumes and gases, carbon dioxide.
【Combustion Products】

Fire may produce irritating, corrosive and/or toxic gases.
Transport InformationBack to Contents
【UN Number】

1993
【Hazard Class】

3
【Packing Group】

I; II; III
Company Name: Wuhan xinyangruihe Chemical Technology Co., Ltd.
Tel: 027-83850375 18120580375
Fax: 027-83850375
WebSite: https://www.chemicalbook.com/ShowSupplierProductsList592397/0.htm
Company Name: J & K SCIENTIFIC LTD.
Tel: 010-82848833 400-666-7788
Fax: 86-10-82849933
WebSite: http://www.jkchemical.com
Company Name: Meryer (Shanghai) Chemical Technology Co., Ltd.
Tel: 4006608290; 18621169109
Fax: 86-21-61259102
WebSite: https://www.meryer.com/cn/index/
Company Name: Alfa Aesar
Tel: 400-6106006
Fax: 021-67582001/03/05
WebSite: http://chemicals.thermofisher.cn
Company Name: TCI (Shanghai) Development Co., Ltd.
Tel: 021-67121386
Fax: 021-67121385
WebSite: https://www.tcichemicals.com/CN/zh/
Company Name: BeiJing Hwrk Chemicals Limted
Tel: 0757-86329057 18501085097
Fax: 010-89508210
WebSite: www.hwrkchemical.com
Company Name: Energy Chemical
Tel: 021-021-58432009 400-005-6266
Fax: 021-58436166
WebSite: http://www.energy-chemical.com
Company Name: Shijiazhuang Sdyano Fine Chemical Co., Ltd.
Tel: 0311-89250318 031166536426
Fax: 4000311741
WebSite: http://www.sdynchem.com