Chemical Safety Data Sheet MSDS / SDS

Methyl lactate

Revision Date:2023-08-05Revision Number:1

SECTION 1: Identification of the substance/mixture and of the company/undertaking

Product identifier

  • Product name: Methyl lactate
  • CBnumber: CB0312448
  • CAS: 547-64-8
  • EINECS Number: 208-930-0
  • Synonyms: methyl lactate,methyl 2-hydroxypropanoate

Relevant identified uses of the substance or mixture and uses advised against

  • Relevant identified uses: For R&D use only. Not for medicinal, household or other use.
  • Uses advised against: none

Company Identification

  • Company: Chemicalbook
  • Address: Building 1, Huihuang International, Shangdi 10th Street, Haidian District, Beijing
  • Telephone: 400-158-6606

SECTION 2: Hazards identification

Classification of the substance or mixture

Flammable liquids, Category 3

Eye irritation, Category 2

Specific target organ toxicity – single exposure, Category 3

Label elements

Pictogram(s)
  • Signal wordWarning
Hazard statement(s)

H226 Flammable liquid and vapour

H319 Causes serious eye irritation

H335 May cause respiratory irritation

Precautionary statement(s)

P210 Keep away from heat/sparks/open flames/hot surfaces. — No smoking.

P261 Avoid breathing dust/fume/gas/mist/vapours/spray.

P303+P361+P353 IF ON SKIN (or hair): Remove/Take off Immediately all contaminated clothing. Rinse SKIN with water/shower.

P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continuerinsing.

P405 Store locked up.

Prevention

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

P233 Keep container tightly closed.

P240 Ground and bond container and receiving equipment.

P241 Use explosion-proof [electrical/ventilating/lighting/...] equipment.

P242 Use non-sparking tools.

P243 Take action to prevent static discharges.

P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...

P264 Wash ... thoroughly after handling.

P261 Avoid breathing dust/fume/gas/mist/vapours/spray.

P271 Use only outdoors or in a well-ventilated area.

Response

P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse affected areas with water [or shower].

P370+P378 In case of fire: Use ... to extinguish.

P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.

P319 Get medical help if you feel unwell.

Storage

P403+P235 Store in a well-ventilated place. Keep cool.

P403+P233 Store in a well-ventilated place. Keep container tightly closed.

P405 Store locked up.

Disposal

P501 Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.

Other hazards

no data available

SECTION 3: Composition/information on ingredients

Substance

  • Product name: Methyl lactate
  • Synonyms: methyl lactate,methyl 2-hydroxypropanoate
  • CAS: 547-64-8
  • EC number: 208-930-0
  • MF: C4H8O3
  • MW: 104.1

SECTION 4: First aid measures

Description of first aid measures

If inhaled

Move the victim into fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration and consult a doctor immediately. Do not use mouth to mouth resuscitation if the victim ingested or inhaled the chemical.

Following skin contact

Take off contaminated clothing immediately. Wash off with soap and plenty of water. Consult a doctor.

Following eye contact

Rinse with pure water for at least 15 minutes. Consult a doctor.

Following ingestion

Rinse mouth with water. Do not induce vomiting. Never give anything by mouth to an unconscious person. Call a doctor or Poison Control Center immediately.

Most important symptoms and effects, both acute and delayed

no data available

Indication of any immediate medical attention and special treatment needed

Immediate first aid: Ensure that adequate decontamination has been carried out. If patient is not breathing, start artificial respiration, preferably with a demand valve resuscitator, bag-valve-mask device, or pocket mask, as trained. Perform CPR if necessary. Immediately flush contaminated eyes with gently flowing water. Do not induce vomiting. If vomiting occurs, lean patient forward or place on the left side (head-down position, if possible) to maintain an open airway and prevent aspiration. Keep patient quiet and maintain normal body temperature. Obtain medical attention. Poisons A and B

SECTION 5: Firefighting measures

Extinguishing media

Suitable extinguishing media: Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Specific Hazards Arising from the Chemical

no data available

Advice for firefighters

Wear self-contained breathing apparatus for firefighting if necessary.

NFPA 704

1
2
0
HEALTH 1 Exposure would cause irritation with only minor residual injury (e.g. acetone, sodium bromate, potassium chloride)
FIRE 2 Must be moderately heated or exposed to relatively high ambient temperature before ignition can occur and multiple finely divided suspended solids that do not require heating before ignition can occur. Flash point between 37.8 and 93.3 °C (100 and 200 °F). (e.g. diesel fuel, sulfur)
REACT 0 Normally stable, even under fire exposure conditions, and is not reactive with water (e.g. helium,N2)
SPEC. HAZ.

SECTION 6: Accidental release measures

Personal precautions, protective equipment and emergency procedures

Avoid dust formation. Avoid breathing mist, gas or vapours.Avoid contacting with skin and eye. Use personal protective equipment.Wear chemical impermeable gloves. Ensure adequate ventilation.Remove all sources of ignition. Evacuate personnel to safe areas.Keep people away from and upwind of spill/leak.

Environmental precautions

Prevent further spillage or leakage if it is safe to do so. Do not let the chemical enter drains. Discharge into the environment must be avoided.

Methods and materials for containment and cleaning up

ACCIDENTAL RELEASE MEASURES: Personal precautions, protective equipment and emergency procedures: Use personal protective equipment. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapors accumulating to form explosive concentrations. Vapors can accumulate in low areas; Environmental precautions: Prevent further leakage or spillage if safe to do so. Do not let product enter drains; Methods and materials for containment and cleaning up: Contain spillage, and then collect with an electrically protected vacuum cleaner or by wet-brushing and place in container for disposal according to local regulations.

SECTION 7: Handling and storage

Precautions for safe handling

Handling in a well ventilated place. Wear suitable protective clothing. Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Use non-sparking tools. Prevent fire caused by electrostatic discharge steam.

Conditions for safe storage, including any incompatibilities

Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Moisture sensitive.

SECTION 8: Exposure controls/personal protection

Control parameters

Occupational Exposure limit values

no data available

Biological limit values

no data available

Exposure controls

Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Set up emergency exits and the risk-elimination area.

Individual protection measures

Eye/face protection

Wear tightly fitting safety goggles with side-shields conforming to EN 166(EU) or NIOSH (US).

Skin protection

Wear fire/flame resistant and impervious clothing. Handle with gloves. Gloves must be inspected prior to use. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Respiratory protection

If the exposure limits are exceeded, irritation or other symptoms are experienced, use a full-face respirator.

Thermal hazards

no data available

SECTION 9: Physical and chemical properties

Information on basic physicochemical properties

  • Physical stateLiquid
  • ColourClear colorless to pale yellow
  • Odour

    no data available

  • Melting point/freezing point

    271°C(lit.)

  • Boiling point or initial boiling point and boiling range

    144°C

  • Flammability

    no data available

  • Lower and upper explosion limit/flammability limit

    Lower flammable limit: : 2.2% by vol @ 212 deg F (100 deg C)

  • Flash point

    54°C(lit.)

  • Auto-ignition temperature

    725 deg F (385 deg C)

  • Decomposition temperature

    no data available

  • pH

    no data available

  • Kinematic viscosity

    2.94 cP at 20 deg C

  • Solubility

    Miscible in water with decomposition

  • Partition coefficient n-octanol/water

    log Kow = -0.67 (est)

  • Vapour pressure

    3.5 mm Hg at 25 deg C

  • Density and/or relative density1.09
  • Relative vapour density1.09
  • Particle characteristics

    no data available

SECTION 10: Stability and reactivity

Reactivity

no data available

Chemical stability

Stable under recommended storage conditions.

Possibility of hazardous reactions

Moderate fire risk.

Conditions to avoid

no data available

Incompatible materials

Incompatible materials: Oxidizing agents, acids, Bases

Hazardous decomposition products

When heated to decomposition it emits acrid smoke and irritating vapors.

SECTION 11: Toxicological information

Acute toxicity

  • Oral: no data available
  • Inhalation: no data available
  • Dermal: no data available

Skin corrosion/irritation

no data available

Serious eye damage/irritation

no data available

Respiratory or skin sensitization

no data available

Germ cell mutagenicity

no data available

Carcinogenicity

no data available

Reproductive toxicity

no data available

STOT-single exposure

no data available

STOT-repeated exposure

no data available

Aspiration hazard

no data available

SECTION 12: Ecological information

Toxicity

  • Toxicity to fish: no data available
  • Toxicity to daphnia and other aquatic invertebrates: EC50; Species: Daphnia magna (Water flea); Conditions: freshwater, static; Concentration: 780000 ug/L for 48 hr (95% confidence interval: 689000-882000 ug/L); Effect: intoxication, decreased mobility /97% purity
  • Toxicity to algae: no data available
  • Toxicity to microorganisms: no data available

Persistence and degradability

AEROBIC: Methyl lactate, present at 2.04 mg/L, reached 76% of its theoretical BOD in 28 days using an activated sludge inoculum in the OECD 301D Method (Closed Bottle Test) which classified the compound as readily biodegradable(1). The similar compound ethyl lactate was found to be readily biodegradable using the Japanese MITI test(2). The lactate ester group of compounds are generally considered to be readily biodegradable(1,3).

Bioaccumulative potential

An estimated BCF of 3 was calculated in fish for methyl lactate(SRC), using an estimated log Kow of -0.67(1) and a regression-derived equation(1). According to a classification scheme(2), this BCF suggests the potential for bioconcentration in aquatic organisms is low(SRC).

Mobility in soil

Using a structure estimation method based on molecular connectivity indices(1), the Koc of methyl lactate can be estimated to be 1(SRC). According to a classification scheme(2), this estimated Koc value suggests that methyl lactate is expected to have very high mobility in soil.

Other adverse effects

no data available

SECTION 13: Disposal considerations

Disposal methods

Product

The material can be disposed of by removal to a licensed chemical destruction plant or by controlled incineration with flue gas scrubbing. Do not contaminate water, foodstuffs, feed or seed by storage or disposal. Do not discharge to sewer systems.

Contaminated packaging

Containers can be triply rinsed (or equivalent) and offered for recycling or reconditioning. Alternatively, the packaging can be punctured to make it unusable for other purposes and then be disposed of in a sanitary landfill. Controlled incineration with flue gas scrubbing is possible for combustible packaging materials.

SECTION 14: Transport information

UN Number

ADR/RID: UN3272 (For reference only, please check.)

IMDG: UN3272 (For reference only, please check.)

IATA: UN3272 (For reference only, please check.)

UN Proper Shipping Name

ADR/RID: ESTERS, N.O.S. (For reference only, please check.)

IMDG: ESTERS, N.O.S. (For reference only, please check.)

IATA: ESTERS, N.O.S. (For reference only, please check.)

Transport hazard class(es)

ADR/RID: 3 (For reference only, please check.)

IMDG: 3 (For reference only, please check.)

IATA: 3 (For reference only, please check.)

Packing group, if applicable

ADR/RID: II (For reference only, please check.)

IMDG: II (For reference only, please check.)

IATA: II (For reference only, please check.)

Environmental hazards

ADR/RID: No

IMDG: No

IATA: No

Special precautions for user

no data available

Transport in bulk according to IMO instruments

no data available

SECTION 15: Regulatory information

Safety, health and environmental regulations specific for the product in question

European Inventory of Existing Commercial Chemical Substances (EINECS)
Listed.
EC Inventory
Listed.
United States Toxic Substances Control Act (TSCA) Inventory
Listed.
China Catalog of Hazardous chemicals 2015
Listed.
New Zealand Inventory of Chemicals (NZIoC)
Listed.
PICCS
Listed.
Vietnam National Chemical Inventory
Listed.
IECSC
Listed.
Korea Existing Chemicals List (KECL)
Listed.

SECTION 16: Other information

Abbreviations and acronyms

  • CAS: Chemical Abstracts Service
  • ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
  • RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
  • IMDG: International Maritime Dangerous Goods
  • IATA: International Air Transportation Association
  • TWA: Time Weighted Average
  • STEL: Short term exposure limit
  • LC50: Lethal Concentration 50%
  • LD50: Lethal Dose 50%
  • EC50: Effective Concentration 50%

References

  • IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
  • HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
  • IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
  • eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
  • CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
  • ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
  • ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
  • Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
  • ECHA - European Chemicals Agency, website: https://echa.europa.eu/
Disclaimer:

The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.

Recommended Products
Methyl lactate SDS Methyl 2-bromopropionate SDS 4-Hydroxybenzoic acid SDS Nisin SDS Ethyl lactate SDS Kresoxim-methyl SDS Lactic acid SDS Methyl 2-chloropropionate SDS Methyl 3-bromopropionate SDS Glycolic acid SDS