Duolink In Situ Wash Buffers, Fluorescence

Duolink In Situ Wash Buffers, Fluorescence Struktur
CAS-Nr.
Englisch Name:
Duolink In Situ Wash Buffers, Fluorescence
Synonyma:
Duolink? In Situ Wash Buffers, Fluorescence
CBNumber:
CB02839145
Summenformel:
Molgewicht:
0
MOL-Datei:
Mol file

Duolink In Situ Wash Buffers, Fluorescence Eigenschaften

storage temp. 
20-25°C
Sicherheit
  • Risiko- und Sicherheitserklärung
  • Gefahreninformationscode (GHS)
WGK Germany  3
Bildanzeige (GHS) GHS hazard pictograms
Alarmwort Warnung
Gefahrenhinweise
Code Gefahrenhinweise Gefahrenklasse Abteilung Alarmwort Symbol P-Code
H315 Verursacht Hautreizungen. Hautreizung Kategorie 2 Warnung GHS hazard pictogramssrc="/GHS07.jpg" width="20" height="20" /> P264, P280, P302+P352, P321,P332+P313, P362
H319 Verursacht schwere Augenreizung. Schwere Augenreizung Kategorie 2 Warnung GHS hazard pictogramssrc="/GHS07.jpg" width="20" height="20" /> P264, P280, P305+P351+P338,P337+P313P
H335 Kann die Atemwege reizen. Spezifische Zielorgan-Toxizität (einmalige Exposition) Kategorie 3 (Atemwegsreizung) Warnung GHS hazard pictogramssrc="/GHS07.jpg" width="20" height="20" />
Sicherheit
P305+P351+P338 BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Eventuell vorhandene Kontaktlinsen nach Möglichkeit entfernen. Weiter spülen.

Duolink In Situ Wash Buffers, Fluorescence Chemische Eigenschaften,Einsatz,Produktion Methoden

Verwenden

Duolink?proximity ligation assay(PLA?) allows for endogenous detection of protein interactions, post translational modifications, and protein expression levels at the single molecule level in fixed cells and tissue samples.

Use the Duolink? In Situ Fluorescence Protocol for this product. A set of short instructionsis also available.

Visit our Duolink? PLA Resource Center for information on how to run a Duolink? experiment, applications, troubleshooting, and more.

To perform a complete Duolink? PLA in situ experiment you will need two primary antibodies (PLA, IHC, ICC or IF validated) that recognize two target epitopes. Other necessary reagents include a pair of PLA probes from different species (one PLUS and one MINUS), detection reagents, wash buffers, and mounting medium. Note that the primary antibodies must come from the same species as the Duolink? PLA probes. Analysis is carried out using standard immunofluorescence assay equipment.

Specificity
Duolink? In Situ fluorescence applications use two wash buffers. Wash Buffer A is used after the PLA Probe incubation step and Wash Buffer B is used after incubation with the amplification reagents. See datasheet for more information.

Application Note
Two primary antibodies raised in different species are needed. Test your primary antibodies (IgG-class, mono- or polyclonal) in a standard immunofluorescence (IF), immunohistochemistry (IHC) or immunocytochemistry (ICC) assay to determine the optimal fixation, blocking, and titer conditions. Duolink?PLA in situ reagents are suitable for use on fixed cells, cytospin cells, cells grown on slide, formalin-fixed, paraffin embedded (FFPE), or tissue (fresh or frozen). No minimum number of cells is required.

Linkage
Let us do the work for you, learn more about our Custom Service Program to accelerate your Duolink? projects

View full Duolink? product list

Duolink In Situ Wash Buffers, Fluorescence Upstream-Materialien And Downstream Produkte

Upstream-Materialien

Downstream Produkte


Duolink In Situ Wash Buffers, Fluorescence Anbieter Lieferant Produzent Hersteller Vertrieb Händler.

Global( 2)Lieferanten
Firmenname Telefon E-Mail Land Produktkatalog Edge Rate
Sigma-Aldrich 021-61415566 800-8193336
orderCN@merckgroup.com China 51471 80

  • Duolink? In Situ Wash Buffers, Fluorescence
Copyright 2019 © ChemicalBook. All rights reserved