AXIS Axon Isolation Device, 150 μm

 化学構造式
CAS番号.
化学名:
别名:
英語名:
AXIS Axon Isolation Device, 150 μm
英語别名:
AXIS Axon Isolation Device, 150 μm
CBNumber:
CB64816892
化学式:
分子量:
0
MOL File:
Mol file

AXIS Axon Isolation Device, 150 μm 物理性質

安全性情報

AXIS Axon Isolation Device, 150 μm 価格

メーカー 製品番号 製品説明 CAS番号 包装 価格 更新時間 購入

AXIS Axon Isolation Device, 150 μm 化学特性,用途語,生産方法

一般的な説明

AXIS Axon Isolation Devices are tissue culture ready (TC) microfluidic tools that out-of-the-box enable researchers to easily isolate, observe, and test developing neurites. They are currently being offered in four different formats to provide test flexibility during investigation.

AX15010 consists of 10 units of AX150, an axon isolation device consisting of four wells, two channels, and a set of microgrooves. Two of the wells are interconnected by a channel on each side of the device. The microgrooves are located in the area between the two channels and their length is 150μm. Each microgroove is approximately 5μm in height by 10μm in width and are designed to allow neurite passage to traverse through while preventing cell bodies from flowing across the device. There are roughly 120 microgrooves in each AX150 device.

The AXIS Axon Isolation Devices have been shown to effectively isolate cell bodies from differentiating neurites for a variety of cell types (Taylor et al., 2005; Park et al., 2006; Liu et al., 2008; Yang, et al., 2009; Taylor et al., 2009) and will likely work with most neuronal cell type that can be successfully grown in tissue culture. Because the AXIS devices are made from an inert and non-toxic polymer, cultures grown within AXIS devices can be maintained for weeks at a time. (Chun et al., 1992; Shibayama et al., 1991). In addition, because the polymer used to fabricate the axon isolation devices is optically clear, cells cultured within the device can be imaged with high resolution microscopy, including live cell imaging, confocal, and differential interference microscopy (Taylor et al., 2005; Park et al., 2006; Liu et al., 2008; Yang, et al., 2009; Taylor et al., 2009).

The microfluidic design of the AXIS devices is highly conducive to generation of hydrostatic pressure, which can be selectively used to isolate a solution, as well as chemical targets of interest, on a designated side of the device (Park et al., 2006). In addition, immunocytochemistry (IHC) can also be performed within an AXIS Axon Isolation device and a protocol to do so is provided in the manual.

AXIS Axon Isolation Device, 150 μm 上流と下流の製品情報

原材料

準備製品


AXIS Axon Isolation Device, 150 μm 生産企業

Global( 2)Suppliers
名前 電話番号 電子メール 国籍 製品カタログ 優位度
Sigma-Aldrich 021-61415566 800-8193336
orderCN@merckgroup.com China 51471 80

  • AXIS Axon Isolation Device, 150 μm
Copyright 2017 © ChemicalBook. All rights reserved