ChemicalBook >>Cadmium chloride hydrate>>Cadmium chloride hemipentahydrate(7790-78-5)

Cadmium chloride hemipentahydrate(7790-78-5)

Cadmium chloride hemipentahydrate(7790-78-5)
Product IdentificationBack to Contents
【Product Name】

Cadmium chloride hemipentahydrate
【Synonyms】

Cadmium dichloride pentahydrate
【CAS】

7790-78-5
【Formula】

2CdCl2.5H2O
【Molecular Weight】

465.78
【RTECS】

EV0178000
【RTECS Class】

Tumorigen; Mutagen; Reproductive Effector
【Beilstein/Gmelin】

22435 (G)
Physical and Chemical PropertiesBack to Contents
【Appearance】

Odorless, colorless or white granules.
【Melting Point】

568
【Density】

2.84 g/cm3
【Usage】

Used for the preparation of cadmium sulfide pigments.
【Vapor Density】

6.3
First Aid MeasuresBack to Contents
【Ingestion】

If victim is conscious and alert, give 2-4 cupfuls of milk or water. Never give anything by mouth to an unconscious person. Get medical aid immediately.
【Inhalation】

Remove from exposure to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical aid.
【Skin】

Flush skin with plenty of soap and water for at least 15 minutes while removing contaminated clothing and shoes. Get medical aid if irritation develops or persists.
【Eyes】

Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Get medical aid.
Handling and StorageBack to Contents
【Storage】

Keep away from sources of ignition. Do not store in direct sunlight. Store in a tightly closed container. Store in a cool, dry, well-ventilated area away from incompatible substances.
【Handling】

Wash thoroughly after handling. Wash hands before eating. Remove contaminated clothing and wash before reuse. Use with adequate ventilation. Minimize dust generation and accumulation. Do not get in eyes, on skin, or on clothing. Do not ingest or inhale. Do not breathe dust.
Hazards IdentificationBack to Contents
【Inhalation】

May cause respiratory tract irritation. Irritation may lead to chemical pneumonitis and pulmonary edema. May cause ulceration and perforation of the nasal septum if inhaled in excessive quantities. May cause pulmonary fibrosis and permanent damage.
【Skin】

Exposure may cause irritation and possible burns.
【Eyes】

Exposure to the substance as an aqueous solution may cause irritation and corneal abnormalities.
【Ingestion】

May cause gastrointestinal irritation with nausea, vomiting and diarrhea. Exposure may cause severe swelling of face and neck areas with possible death.
【Hazards】

Contact with metals may evolve flammable hydrogen gas.
【UN (DOT)】

2570
Exposure Controls/Personal ProtectionBack to Contents
【Personal Protection】

Eyes: Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166. Skin: Wear appropriate gloves to prevent skin exposure. Clothing: Wear appropriate protective clothing to prevent skin exposure.
【Respirators】

A respiratory protection program that meets OSHA's 29 CFR 1910.134 and ANSI Z88.2 requirements or European Standard EN 149 must be followed whenever workplace conditions warrant a respirator's use.
【Exposure Effects】

May cause respiratory tract cancer. Prolonged or repeated exposure may cause permanent bone structure abnormalities. May cause liver and kidney damage. Chronic inhalation may cause nasal septum ulceration and perforation. Chronic inhalation of cadmium compounds has been associated with lung and prostrate cancer.
【Exposure limit(s)】

5 µg/m3 PEL {2 µg/m3 respirable TLV}
Fire Fighting MeasuresBack to Contents
【Fire Fighting】

Wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. Water runoff can cause environmental damage. Dike and collect water used to fight fire. Dusts may be combustible when exposed to heat, flame, or oxidizing agents. Extinguishing media: For small fires, use water spray, dry chemical, carbon dioxide or chemical foam. Substance is noncombustible; use agent most appropriate to extinguish surrounding fire.
【Fire Potential】

Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes.
Accidental Release MeasuresBack to Contents
【Small spills/leaks】

Vacuum or sweep up material and place into a suitable disposal container. Avoid generating dusty conditions. Provide ventilation.
Stability and ReactivityBack to Contents
【Incompatibilities】

Bromine trifluoride, hydrogen azide, oxidizers, potassium, selenium, tellurium and zinc.
【Stability】

Stable at room temperature in closed containers under normal storage and handling conditions.
【Decomposition】

Cadmium fumes, chloride fumes.
【Combustion Products】

Fire may produce irritating, corrosive and/or toxic gases.
Transport InformationBack to Contents
【UN Number】

2570
【Hazard Class】

6.1
【Packing Group】

I; II; III
Company Name: SHENYANG SINOCHEM BIOTECH CO.,LTD
Tel: 024-23769576 13840269002
Fax:
WebSite: www.sinochembt.cn/
Company Name: J & K SCIENTIFIC LTD.
Tel: 010-82848833 400-666-7788
Fax: 86-10-82849933
WebSite: http://www.jkchemical.com
Company Name: Meryer (Shanghai) Chemical Technology Co., Ltd.
Tel: 4006608290; 18621169109
Fax: 86-21-61259102
WebSite: https://www.meryer.com/cn/index/
Company Name: Alfa Aesar
Tel: 400-6106006
Fax: 021-67582001/03/05
WebSite: http://chemicals.thermofisher.cn
Company Name: BeiJing Hwrk Chemicals Limted
Tel: 0757-86329057 18501085097
Fax: 010-89508210
WebSite: www.hwrkchemical.com
Company Name: Shanghai Hanhong Scientific Co.,Ltd.
Tel: 021-54306202 13764082696;
Fax:
WebSite: https://www.hanhongsci.com
Company Name: Shandong Xiya Chemical Co., Ltd
Tel: 13355009207 13355009207
Fax: 0539-6365991
WebSite: www.xiyashiji.com
Company Name: Maya High Purity Chemicals
Tel: +86 (573) 82222445 (0)18006601000 452520369
Fax: +86 (573) 82222643
WebSite: www.chemicalbook.com/ShowSupplierProductsList15221/0.htm