Product Identification | Back to Contents | 【Product Name】
6-(Trifluoromethoxy)-1,3-benzothiazol-2-amine | 【Synonyms】
2-Amino-6-trifluoromethoxybenzothiazole 2-Benzothiazolamine, 6-(trifluoromethoxy)- 6-(Trifluoromethoxy)-2-aminobenzothiazole Benzothiazole, 2-amino-6-trifluoromethoxy- Rilutek | 【CAS】
1744-22-5 | 【Formula】
C8H5F3N2OS | 【Molecular Weight】
234.2 | 【RTECS】
DL2830000 | 【Merck】
12,8389 |
Physical and Chemical Properties | Back to Contents | 【Appearance】
Powder. | 【Solubility in water】
Insoluble | 【Melting Point】
117 | 【Boiling Point】
296 | 【Vapor Pressure】
0.0015 (25 C) | 【Density】
1.572 g/cm3 (20 C) | 【pKa/pKb】
10.45 (pKb) | 【Partition Coefficient】
2.84 | 【Heat Of Vaporization】
53.6 kJ/mol | 【Usage】
Used to treat amyotrophic lateral sclerosis. |
First Aid Measures | Back to Contents | 【Ingestion】
Do not induce vomiting without medical advice. | 【Inhalation】
Move to fresh air. Call a physician immediately. | 【Skin】
Rinse immediately with plenty of water and seek medical advice. | 【Eyes】
In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice. |
Exposure Controls/Personal Protection | Back to Contents | 【Personal Protection】
PVC or other plastic gloves. Protective work clothing. Safety glasses with side-shields. | 【Exposure Effects】
Chronic toxicity: Chronic exposure may cause nausea and vomiting, higher exposure causes unconsciousness. Local effects: Symptoms of overexposure may be headache, dizziness, tiredness, nausea and vomiting. Specific effects: May include moderate to severe erythema (redness) and moderate edema (raised skin), nausea, vomiting, headache. |
Fire Fighting Measures | Back to Contents | 【Flash Point】
133 | 【Fire Fighting】
Extinguish using dry chemical, CO2, water spray or alcohol foam. Wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear. Water mist may be used to cool closed containers. |
Accidental Release Measures | Back to Contents | 【Small spills/leaks】
Eliminate all ignition sources. Absorb and/or contain spill with inert materials (e.g., sand, vermiculite). Then place in appropriate container. For large spills, use water spray to disperse vapors, flush spill area. Prevent runoff from entering waterways or sewers. |
|
Company Name: |
J & K SCIENTIFIC LTD. |
Tel: |
010-82848833 400-666-7788 |
Fax: |
86-10-82849933 |
WebSite: |
http://www.jkchemical.com |
Company Name: |
Alfa Aesar |
Tel: |
400-6106006 |
Fax: |
021-67582001/03/05 |
WebSite: |
http://chemicals.thermofisher.cn |
Company Name: |
Energy Chemical |
Tel: |
021-021-58432009 400-005-6266 |
Fax: |
021-58436166 |
WebSite: |
http://www.energy-chemical.com |
|