ChemicalBook >>Halobetasol propionate>>Ulobetasol propionate(66852-54-8)

Ulobetasol propionate(66852-54-8)

Ulobetasol propionate(66852-54-8)
Product IdentificationBack to Contents
【Product Name】

Ulobetasol propionate
【Synonyms】

Pregna-1,4-diene-3,20-dione, 21-chloro-6,9-difluoro-11-hydroxy-16-methyl-17-(1-oxopropoxy)-, (6-alpha,11-beta,16-beta)
Ulobetasol propionate
Ultravate
【CAS】

66852-54-8
【Formula】

C25H31ClF2O5
【Molecular Weight】

484.97
【RTECS】

TU3723500
【Merck】

12,4625
Physical and Chemical PropertiesBack to Contents
【Appearance】

Distributed as 0.05% ointment.
【Solubility in water】

Insoluble
【Melting Point】

220 - 221
【Vapor Pressure】

2.1E-15 (25 C)
【Density】

1.31 g/cm3 (20 C)
【pKa/pKb】

12.58 (pKa)
【Partition Coefficient】

3.73
【Usage】

Topical corticosteroid.
First Aid MeasuresBack to Contents
【Ingestion】

Give 2-4 cups of milk or water to dilute. Never give anything by mouth to an unconscious person.
【Inhalation】

Not applicable with normal use. In cases of overexposure, remove to fresh air. If breathing is difficult, give oxygen. If breathing has stopped, give artificial respiration. Contact a physician.
【Skin】

Wash immediately and thoroughly with soap and water. If redness, itching or burning sensation develops, get medical attention.
【Eyes】

Flush immediately with plenty of water for at least 15 minutes.
Handling and StorageBack to Contents
【Storage】

Product should be stored in cool, dry place, away from sources of heat. Store between 15 and 30 C.
Fire Fighting MeasuresBack to Contents
【Fire Fighting】

Extinguishing agents: Water, Carbon Dioxide, Dry Chemical, Foam. Wear self-contained breathing apparatus.
Accidental Release MeasuresBack to Contents
【Small spills/leaks】

Assure slippery conditions are nullified. Add sand or dirt. Scoop up and remove to plastic-lined fiber containers immediately. Dispose of in accordance with federal, state and local regulations.
Stability and ReactivityBack to Contents
【Incompatibilities】

Oxidizing agents, bases.
【Stability】

stable at normal temperatures and pressures.
Exposure Controls/Personal ProtectionBack to Contents
【Exposure Effects】

May cause irritation of skin and eyes. May cause mutagen and reproductive effects. May cause suppression of HPA axis, gastrointestinal upset and temporary CNS depression. Kidney disorders, hypersensitivity to any of the components.
Company Name: WUHAN MEIAN BIOMEDICINE TECHNOLOGY Co., Ltd,
Tel: 15377551262
Fax:
WebSite: https://www.chemicalbook.com/ShowSupplierProductsList1659329/0.htm
Company Name: Changsha Qisheng Heyan Medical Technology Co., LTD
Tel: 18684929597
Fax:
WebSite: www.chemicalbook.com/showsupplierproductslist292875/0.htm
Company Name: J & K SCIENTIFIC LTD.
Tel: 010-82848833 400-666-7788
Fax: 86-10-82849933
WebSite: http://www.jkchemical.com
Company Name: TCI (Shanghai) Development Co., Ltd.
Tel: 021-67121386
Fax: 021-67121385
WebSite: https://www.tcichemicals.com/CN/zh/
Company Name: Energy Chemical
Tel: 021-021-58432009 400-005-6266
Fax: 021-58436166
WebSite: http://www.energy-chemical.com
Company Name: Adamas Reagent, Ltd.
Tel: 400-6009262 16621234537
Fax: 021-64823266
WebSite: www.tansoole.com
Company Name: Chemsky(shanghai)International Co.,Ltd.
Tel: 021-50135380
Fax:
WebSite: www.shchemsky.com
Company Name: China DongFan Chemical Co.,LTD
Tel: 86-0571-85151182
Fax: 86-0571-85151182
WebSite: www.chemicalbook.com/ShowSupplierProductsList14819/0.htm